Sunday, September 01, 2013

High frequency oscillation in ARDS treatment: disappointing as an initial modality

High frequency oscillation (HFOV) has been recognized as a rescue modality for patients with ARDS refractory to conventional ventilation. Two papers in NEJM recently addressed HFOV as an initial modality of ventilation.

High-Frequency Oscillation in Early Acute Respiratory Distress Syndrome:

Methods
In a multicenter, randomized, controlled trial conducted at 39 intensive care units in five countries, we randomly assigned adults with new-onset, moderate-to-severe ARDS to HFOV targeting lung recruitment or to a control ventilation strategy targeting lung recruitment with the use of low tidal volumes and high positive end-expiratory pressure...
Results
On the recommendation of the data monitoring committee, we stopped the trial after 548 of a planned 1200 patients had undergone randomization. The two study groups were well matched at baseline. The HFOV group underwent HFOV for a median of 3 days (interquartile range, 2 to 8); in addition, 34 of 273 patients (12%) in the control group received HFOV for refractory hypoxemia. In-hospital mortality was 47% in the HFOV group, as compared with 35% in the control group (relative risk of death with HFOV, 1.33; 95% confidence interval, 1.09 to 1.64; P=0.005). This finding was independent of baseline abnormalities in oxygenation or respiratory compliance. Patients in the HFOV group received higher doses of midazolam than did patients in the control group (199 mg per day [interquartile range, 100 to 382] vs. 141 mg per day [interquartile range, 68 to 240], P less than 0.001), and more patients in the HFOV group than in the control group received neuromuscular blockers (83% vs. 68%, P less than 0.001). In addition, more patients in the HFOV group received vasoactive drugs (91% vs. 84%, P=0.01) and received them for a longer period than did patients in the control group (5 days vs. 3 days, P=0.01).


High-Frequency Oscillation for Acute Respiratory Distress Syndrome:

Methods
In a multicenter study, we randomly assigned adults requiring mechanical ventilation for ARDS to undergo either HFOV with a Novalung R100 ventilator (Metran) or usual ventilatory care. All the patients had a ratio of the partial pressure of arterial oxygen (PaO2) to the fraction of inspired oxygen (FiO2) of 200 mm Hg (26.7 kPa) or less and an expected duration of ventilation of at least 2 days...
Results
There was no significant between-group difference in the primary outcome, which occurred in 166 of 398 patients (41.7%) in the HFOV group and 163 of 397 patients (41.1%) in the conventional-ventilation group (P=0.85 by the chi-square test).

Related editorial here.

It may have a niche for patients who fail conventional mechanical ventilation but is not recommended for initial treatment.

No comments: